HLK-LD2410C Support Centre — installation, pinout, Bluetooth configuration, distance tuning, ESP32/ESPHome, Home Assistant, firmware and troubleshooting. This guide is for the LD2410C (22 × 16mm); the original LD2410 and LD2410B have different physical pin arrangements.
- 5V recommended supply (>200mA)
- TX, RX, OUT, GND, VCC
- 3.3V UART, default 256000 baud
- Bluetooth via HLKRadarTool
- ESPHome requires an external ESP32
- Typical indoor detection around 5m
1. Before you begin
This is a bare 24GHz FMCW radar component. It is not a stand-alone Wi-Fi or Zigbee device. For basic presence indication use its OUT signal; for advanced settings and Home Assistant connect it to a compatible host controller by UART.
Required: a regulated 5V power source, suitable wiring or header connections, and optionally an ESP32 development board or a USB-to-UART adapter with 3.3V signalling. Never apply 5V logic to TX/RX/OUT.
2. Identify the correct module and pinout
The LD2410C board measures approximately 22 × 16mm and its five signal pads are labelled on the PCB. With the antenna/component side facing you and the pad row at the top, the printed order is TX – RX – OUT – GND – VCC. Check the silkscreen before wiring.
| TX | Radar UART transmit — to host RX |
|---|---|
| RX | Radar UART receive — to host TX |
| OUT | Digital presence output, normally HIGH on detection (3.3V logic; firmware settings can affect behaviour) |
| GND | Common ground |
| VCC | Power input; stable 5V recommended, supply capacity above 200mA |
3. Quick start: OUT pin only
- Connect VCC to a stable 5V supply and GND to ground.
- Connect OUT to a 3.3V-compatible digital input on your controller (common ground required).
- Wait for the module to stabilise and move through the field of view. Presence should make OUT HIGH under default settings.
- Observe the configured no-person delay; the output may remain HIGH briefly after motion stops or the person leaves.
Use the UART interface when you need moving/still classification, distance or thresholds. An OUT connection by itself does not provide detailed radar measurements.
4. Set up Bluetooth with HLKRadarTool
- Power the LD2410C and enable Bluetooth on your smartphone.
- Install the manufacturer’s HLKRadarTool application from the official download page linked below.
- Open the app and scan for a nearby LD2410-family radar device. The advertised name can vary by firmware.
- Select the device, then enter the default control password HiLink (case sensitive), if prompted.
- View the moving/still energy values, configure sensitivity and maximum gates, then save settings to the device.
Use the app near the radar (the older manual suggests within approximately 4m). Bluetooth is for setup and does not turn the module into a native Home Assistant Bluetooth device.
Official HLKRadarTool download page (Android / iOS)
5. Distance gates, sensitivity and timeout
Each standard distance gate represents approximately 0.75m. You can configure maximum moving and still gates separately; the standard selectable limits extend to 6m (gate 8). The manufacturer’s introductory text describes a typical maximum detection range around 5m.

| Moving threshold | Controls movement sensitivity for each distance interval. |
|---|---|
| Still threshold | Controls sensitivity to micro-movements / comparatively still occupants. |
| Lower value | More sensitive; can increase false detections. |
| Higher value | Less sensitive; setting a gate threshold to 100 generally suppresses that gate. |
| Presence timeout | Time the radar continues reporting presence after it no longer detects a qualifying target. |
Recommended first calibration
- Mount the sensor in its final intended position, not loose on a desk.
- Check readings with the room empty (fans, moving curtains and nearby appliances operating).
- Limit the maximum gate to the area you want covered.
- Increase thresholds only at gates affected by false triggers, then test with a person sitting quietly.
- Adjust the timeout to suit your automation, for example a longer delay for lighting.
6. Install with ESP32, ESPHome and Home Assistant
Connect radar TX → ESP32 RX, radar RX → ESP32 TX, radar GND → ESP32 GND, and radar VCC → 5V. The example wiring uses GPIO16 (RX) and GPIO17 (TX) on a classic ESP32 DevKit. Those GPIOs are examples, not universal across ESP32-C3/S3 boards.
- Install and open ESPHome.
- Create an ESP32 device, add a hardware UART at 256000 baud, 8 data bits, no parity, 1 stop bit.
- Add the built-in
ld2410component and sensor entities. - Flash the ESP32, connect it to Wi-Fi and add the ESPHome device to Home Assistant.
- Use Presence, Moving Target, Still Target and distance/energy values for automations.
A ready-to-adapt YAML file is included in the downloadable Selectro support package. The example is for a classic ESP32 DevKit, not an ESP32-C3 or S3.
Useful entities in ESPHome
| Presence | Detected target of any supported type |
|---|---|
| Moving Target | Movement detected |
| Still Target | Small movement / still-target classification |
| Moving / Still Distance | Approximate radial distance of detected target |
| Moving / Still Energy | Strength used for sensitivity tuning |
| Maximum gates and timeout | Adjustable settings exposed by ESPHome |
| Engineering mode | Temporary diagnostic data; disable when not needed |
Use the official ESPHome LD2410 component documentation for additional controls. Some features are firmware-dependent.
7. Installation and enclosure

- Wall mount: approximately 1.5–2m above floor level.
- Ceiling mount: approximately 2.6–3m, depending on installation.
- Face the radar antenna towards the area you want to detect and mount it securely.
- Avoid moving fans, swaying plants, curtains, strong metal reflections and vibration.
- Use a non-metallic, radar-transparent cover if concealing the board; avoid metallic coatings in front of the antenna.
8. Firmware and software updates
- Check and record the existing radar firmware version before updating.
- Use the official HLKRadarTool app to check whether an update is offered for the identified module.
- Keep the phone close, maintain stable power and do not interrupt an OTA update.
- Never flash firmware for another LD2410 variant unless Hi-Link explicitly confirms compatibility.
Manufacturer documentation states that BLE OTA updating requires compatible firmware (for the older manual: V1.07.22091516 or newer). An update is not necessary when the sensor works correctly; avoid updating just to change version numbers.
9. Troubleshooting
| No response from the module | Verify regulated 5V, shared GND, supply current and PCB pad orientation. |
|---|---|
| UART data missing | Check TX/RX crossed, UART baud 256000 8N1, and 3.3V logic. Use a hardware UART. |
| Present all the time | Reduce maximum distance, increase problematic gate thresholds, investigate fans, curtains and reflections. |
| Does not detect a seated person | Adjust still sensitivity and mounting angle; test at close range first. |
| OUT status does not match ESPHome | Review timeout, output/light options and firmware; UART reporting is the better diagnostic. |
| App cannot find radar | Check power, phone Bluetooth permissions and whether radar Bluetooth is disabled. |
| Distance jumps or behaves oddly | Move the radar away from reflective metal, improve mounting and allow for variable target characteristics. |
| Home Assistant sees no device | Check ESPHome is online over Wi-Fi and native API integration is configured on the ESP32. |
10. Frequently asked questions
Does LD2410C connect directly to Wi-Fi or Zigbee?
No. It provides UART, a presence OUT pin and Bluetooth configuration. Wi-Fi/Home Assistant integration normally uses an external ESP32 or another controller.
Can it detect someone sitting still?
It is designed to detect micro-movements characteristic of sitting or resting people, but no radar can guarantee presence detection of every completely motionless person in all conditions.
Can I track three people like the LD2450?
No. The LD2410C is a presence sensor, not a multi-target X/Y position tracker. Choose LD2450 for supported tracking applications.
Does the module come with an ESP32 or cables?
The product listing is for the radar component only unless the seller explicitly states otherwise. Verify your own package contents.
Why does a 6m setting not guarantee 6m detection?
6m is a maximum configurable distance limit. Actual range depends on target orientation, movement, environmental reflections, enclosure and sensitivity settings.
11. Official resources
- Hi-Link LD2410C user manual V1.00 (English, PDF)
- Hi-Link documentation download centre
- Hi-Link HLKRadarTool official app
- ESPHome LD2410 integration
Document scope: Selectro customer quick-start and support article for HLK-LD2410C. Based on Hi-Link LD2410C V1.00 English manual, manufacturer V1.09 reference and ESPHome documentation reviewed in November 2026. The official manufacturer manual remains the authority for electrical and regulatory details